Rotor of Squirrel Cage Induction Motor

Thursday, October 8, 2020

Power Factor

 Power Factor

Power factor is normally the phase difference between the voltage and current. Power factor is due to the inductive nature of the circuit, however, in resistor the voltage and current are in phase with each other. So, the power factor of the resistive load is unity and reactive power is zero. All the power is active power in resistor. Power Factor is the cosine of active power and he reactive power and maximum value of cosine is one. Therefore the power factor of a load can never be more than one.

  • Power factor is said to be lagging when the current lags the voltage by some angle, due to the inductive nature of the load. 
  • Power factor said to be leading if the current leads the voltage by some angle, due to the capacitive nature of the load.

Active Power:

Active power the main power which is consumed by the load. The main components of power which is used by the ac circuit to do some work. It is measured in KW.

Reactive Power:

Reactive power is the component of the total power which is travel along the active power but not used by the load. It  just travel back and froth in the load. It is used to establish the magnetic field in the motor or other alternating current equipment.

Apparent Power:

The total of the active power and the reactive power is known as apparent power

Electrical Motor : Comparison


Synchronous Motor Vs Induction Motor

Speed Vs Load:

In Induction motor and DC motor, the speed decreases when we increases the load. The decrease in the speed reduces the counter EMF, the additional current is drawn from the motor. If we add more load on the motor, the motor will draw more current which increase the iron losses and more heat will be dissipated, that can cause failure of insulation, faults can occur.

In Synchronous motor, the speed doesn't decrease with the increase in the load, it runs at synchronous speed at all loads. It meets the increased load by the relative shift btw the rotor and stator poles i,e by the adjustment of the torque angle. If the motor load increases , the torque angle increase which causes a greater phase shift of back EMF w.r.t supply voltage. This increases the voltage in stator winding and consequently, armature current will be drawn .

Disconnection of one phase:

If one phase of the three phase motor is disconnected due to some faults, more current will be drawn from the remaining two phase which can cause many failure. It also increases the iron losses. If it continue to draw more current , there can be motor failure or motor burnout.

Power Factor:

Synchronous motor can operate from lagging to leading power factor while the induction operates at the lagging power factor. A synchronous motor can generate and absorb reactive power by adjusting the excitation of the motor. Overexcited synchronous motor under no load condition can be used for power factor corrective device and known as synchronous condenser.

Supply :

Synchronous motor are doubly fed motors: Rotor require dc excitation and Stator require 3 phase ac supply. Induction motor only require 3 phase AC supply.

Self-starting:

Induction motor is self starting because of this construction: Squirrel cage helps the motor to be self starting.
Synchronous motor is not self starting, it require extra dc excitation at the rotor to produce magnetic pole to get lock with synchronous magnetic field revolving around the rotor.






Friday, October 2, 2020

Capacitor

Electrolytic capacitor:

Electrolytic capacitor uses electrolyte to achieve large value of capacitance than the other capacitor types.
Electrolytic capacitor always connected in forward bias ie Anode voltage must be in  higher voltage than the cathode voltage. If it is connected in reversed bias it act as a short circuit 

Application :
It is used power supply as a filtrating devices to reduce the ripple in voltage.
And 
In the low pass filter for the input and output smoothing and doesn't work in large amplitude and high frequency signal.
Electrolytic Capacitor
Electrolytic Capacitor

Capacitance:

Capacitance is the measurement of charge stored in the capacitor. Farad is the S.I. unit of capacitance.
We generally, don't use 1 farad of capacitance because 1 farad is a huge value of capacitance, if we want to make a  1 Farad capacitor, it will occupy a half space in your room.
However, we uses very less power capacitance for household purposes. Generally we uses 2.25 microfarad capacitor in our 220v Fan and all our tv, computer  and laptop have capacitor have capacitor which have value:1*10-12.

Ceramic Capacitor:

Ceramic capacitor is a fixed value capacitor which is made up of ceramic dielectric that's why gets the name: ceramic capacitor. Ceramic capacitor are small in size and are in the range of few picofarad to microfarad. These are used for coupling and decoupling applications.
 



Sunday, September 27, 2020

Types Of DC Motor / Induction Motor & Characterstics

Friday, September 25, 2020

Load Factor

 Load Factor

Load factor is define as average power consumption over a period to the peak power consumption over the same period. Load factor is very important in determining the generation of  cost per unit. Higher the load factor , lesser is the generation cost.

Load factor is calculated:

  • Daily
  • Weekly
  • Monthly 
  • Yearly
Load factor must always be less than one. We should never use all the equipment's of our house simultaneously. If one high power equipment is running ,we should not turn on the second equipment, wait and turn on the the other equipment's when the first work is finished.  

This will improve the load factor and giving us the low generating power cost